Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Influence of additional heating on the microhardness of glass-ionomer cements (CROSBI ID 616800)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Gavić, Lidia ; Goršeta, Kristina ; Tadin , Antonija ; Biočina Lukenda, Dolores ; Glavina, Domagoj Influence of additional heating on the microhardness of glass-ionomer cements // Journal of dental research. 2014. str. 393-393

Podaci o odgovornosti

Gavić, Lidia ; Goršeta, Kristina ; Tadin , Antonija ; Biočina Lukenda, Dolores ; Glavina, Domagoj

engleski

Influence of additional heating on the microhardness of glass-ionomer cements

Objective: The objectives of this study were to verify for various GIC products, whether the application of external heat on the initial curing material, produces an increase in microhardness, and to determine whether this hardness varies, dependent of the depths in the GIC samples. Moreover, the efficacy was examined of various polymerization units on this additional hardening. Method: The GICs samples were thermo-cured for 60s with three polymerization units. The Vickers micro- hardness was measured at three different depths: 2, 3 and 4 mm. The statistical analysis was performed by one-way ANOVA, Newman-Keuls test and linear regression analysis. Statistical significance was set to p<0.05. Result: Analysis of variance and Newman-Keuls test showed statistically significant difference among tested groups for all three GICs. The results of linear regression analysis showed statistically significant correlation between the hardness of the material and temperature for 2 mm (R=0.78 ; p=0.0028) and 3 mm depth (R=0.59 ; p=0.045). Conclusion: The results of this study indicate that thermal-curing of GIC with different polymerization units for 60s during setting reaction increases the microhardness of the GICs at all depths, and consequently resistance to mastication forces which is extremely important for clinical success of restorations

dental materials ; glass ionomers and microhardness

Sažeci sa kongresa objavljeni u tisanom obliku

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

393-393.

2014.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Journal of dental research

0022-0345

1544-0591

Podaci o skupu

IADR/PER Congress

poster

10.09.2014-13.09.2014

Dubrovnik, Hrvatska

Povezanost rada

Dentalna medicina

Indeksiranost