Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

ASSR and ABR -A comparison of treshold in infants (CROSBI ID 616977)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa | međunarodna recenzija

Borut, Marn ; Vlahović, Sanja ASSR and ABR -A comparison of treshold in infants // Journal of Hearing Science / Skarzynski, H. (ur.). 2011. str. 80-80

Podaci o odgovornosti

Borut, Marn ; Vlahović, Sanja

engleski

ASSR and ABR -A comparison of treshold in infants

Compared to ASSR and ABR is a new method of objective hearing treshold evaluation in children. There is a need for more data of comparing these methods especially in hearing impaired children. We studied how methods correlated for each and stimulus, and what a treshold difference (TD) was by frequencies. Methods : The evaluation included all infants who were referred to our audiogy units, in total 61 infants (122 ears) at the age from 1- 60 months (median 11, mean 17, 9). The tresholds of ABR were evaluated by narrow bnd CE chirps of 500 and 1000 HZ and by chirp stimulation on 500, 1000, 2000, ad 4000 HZ.Both methods were applied un all cases in the same session. Results: The correlation between thresholds oh both werer calculated by linear regression. TD for small all stimuli of both methods were analysed as well. The number of data was different for each frequency, beacause sime children had woken strongly before the test was completed. Multiple ASSR tresholds were strongly correlated with frequency specific ABR stimuli (r = 0, 85, , 0, 92, 0, 94) for 500, 1000 and 2000/4000 Hz, respecively.Mean TDs (ASSR minus ABR +- ISD) were 8, 8 (8, 4), 6, 7, 6.7 (6, 9) and 8, 9 (7, 9) respecively. Conclusion : The results indicated that the multiple ASSR and frequency ABR tresholds were strongly correlated. The distribution of TD in the range of +- was 82 % for 500 HZ and 90 % for 1000 HZ, while distribution of TD for 2000)4000 HZ was 72% in the range of 0 to 10 Db (90 % in the range of 0 to 20 db).

ASSR ; ABR ; treshold ; infants

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

80-80.

2011.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Journal of Hearing Science

Skarzynski, H.

Nadarzyn: Institute of Sensory Organs

2083-389X

Podaci o skupu

10th European Federation of Audiology Societies (EFAS) Congress

poster

09.06.2011-11.06.2011

Kajetany, Poljska

Povezanost rada

Kliničke medicinske znanosti