Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis (CROSBI ID 93798)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Ivanković, Dušica ; Pavičić, Jasenka ; Raspor, Biserka ; Falnoga, Ingrid ; Tušek-Žnidarič, Magda Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis // International journal of environmental analytical chemistry, 83 (2003), 3; 219-231-x

Podaci o odgovornosti

Ivanković, Dušica ; Pavičić, Jasenka ; Raspor, Biserka ; Falnoga, Ingrid ; Tušek-Žnidarič, Magda

engleski

Comparison of two SH-based methods for estimation of metallothionein level in the digestive gland of naturally occurring mussels, Mytilus galloprovincialis

Two methods for the evaluation of MT level in M.galloprovincialis digestive gland homogenate extract, polarographic and spectrophotometric, were compared in combination with sample subjected to heat treatment (at 70oC and 85oC) as well as to solvent precipitation. Spectrophotometric measurements ranging within 0.081- 0.144 mg MTg-1 were at least one order of magnitude lower in comparison with the polarographic ones (2.21-2.88 mg MTg-1) depending on the particular sample treatment as well as two specific reagents and reference standards applied. Sephadex G-75 column chromatography of the differently treated samples and subsequent polarographic analysis in the pooled elution fractions indicated that a level of non-MT interfering thiolic component in homogenate extract may be accounted for more than 50% of the total polarographic signal, irrespective of a method of sample treatment applied. Consequently, the large discrepancy between methods could not be attributed only to the sample treatment procedures but more likely to certain not entirely explained analytical problems, particulary calibration with appropriated reference standard.

Metallothionein; MT quantification; Mytilus galloprovincialis; biomarker; biomonitoring

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

83 (3)

2003.

219-231-x

objavljeno

0306-7319

Povezanost rada

Geologija, Kemija, Biologija

Indeksiranost