SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE (CROSBI ID 623630)

Prilog sa skupa u zborniku | izvorni znanstveni rad

Matijević, Mario ; Pevec, Dubravko ; Trontl, Krešimir SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE // Proceedings of the 10th Symposium of the CROATIAN RADIATION PROTECTION ASSOCIATION / Petrinec, Branko ; Bituh, Tomislav ; Milić, Mirta et al. (ur.). Zagreb: CROATIAN RADIATION PROTECTION ASSOCIATION, 2015. str. 408-413

Podaci o odgovornosti

Matijević, Mario ; Pevec, Dubravko ; Trontl, Krešimir

engleski

SCALE6.1 HYBRID SHIELDING METHODOLOGY FOR THE SPENT FUEL DRY STORAGE

The SCALE6.1/MAVRIC hybrid deterministic- stochastic shielding methodology was used for dose rates calculation of the generic spent fuel dry storage installation. The neutron-gamma dose rates around the cask array were calculated over a large problem domain in order to determine the boundary of the controlled area. The FW-CADIS methodology, based on the deterministic forward and adjoint solution over the phase-space, was used for optimized, global Monte Carlo results over the mesh tally. The cask inventory was modeled as homogenized material corresponding to 20 fuel assemblies from a standard mid-sized PWR reactor. The global simulation model was an array of 32 casks in 2 rows with concrete foundations and external air, which makes a large spatial domain for shielding calculations. The dose rates around the casks were determined using FW-CADIS method with weighted adjoint source and mesh tally covering a portion of spatial domain of interest. The conservatively obtained dose rates give the upper boundary, since the activation reduction of sources was not taken into account when sequential filling of the dry storage will start. The effective area of the dry storage installation can be additionally reduced with lowering concrete foundation under the ground, embankment raising, and with extra concrete walls, that would additionally lower the dominant gamma dose rates.

Shielding; SCALE6.1; Monte Carlo; cask; FW-CADIS; dose rates

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

408-413.

2015.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 10th Symposium of the CROATIAN RADIATION PROTECTION ASSOCIATION

Petrinec, Branko ; Bituh, Tomislav ; Milić, Mirta ; Kopjar, Nevenka

Zagreb: CROATIAN RADIATION PROTECTION ASSOCIATION

1849-5060

Podaci o skupu

10th Symposium of the Croatian Radiation Protection Association with international participation

predavanje

15.04.2015-17.04.2015

Šibenik, Hrvatska

Povezanost rada

Elektrotehnika