Validation of EZ1® Advanced XL workstation using EZ1 Investigator Kit (CROSBI ID 626230)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Abramović, Marko Krešimir ; Barbarić, Lucija ; Valić, Marija ; Merkaš, Siniša ; Rožić, Sara ; Sukser, Viktorija ; Uvodić, Petra ; Crnjac, Josip ; Popović, Maja ; Ortynski, Nataša et al. Validation of EZ1® Advanced XL workstation using EZ1 Investigator Kit // International Society for Applied Biological Sciences, Program and Abstracts, 9th ISABS Conference on Forensic, Anthropological Genetics and Mayo Clinic Lectures in Individualized Medicine / Kayser M., Ordog T., Vuk-Pavlović S., Primorac D., Schanfield M. (ur.). Zagreb: Grafički zavod Hrvatske, 2015. str. 113-113

Podaci o odgovornosti

Abramović, Marko Krešimir ; Barbarić, Lucija ; Valić, Marija ; Merkaš, Siniša ; Rožić, Sara ; Sukser, Viktorija ; Uvodić, Petra ; Crnjac, Josip ; Popović, Maja ; Ortynski, Nataša ; Mršić, Gordan

engleski

Validation of EZ1® Advanced XL workstation using EZ1 Investigator Kit

With the ongoing need to constantly improve techniques that laboratories use for isolation and purification of DNA, we introduce EZ1® Advanced XL instrument for automated isolation and purification of DNA alongside with EZ1 Investigator Kit into our laboratory casework. The aim of this study was to compare existing Chelex®100 method with EZ1® Advanced XL workstation, and to determine accuracy, reliability, and flexibility of EZ1 Investigator kit. Genomic DNA was isolated from whole blood, buccal swabs and forensic samples. The genomic DNA content of each sample was determined by quantitative real-time polymerase chain reaction (PCR) using Quantifiler® Human DNA Quantification Kit and Investigator Quantiplex kit, respectively. Amplification was performed using AmpFlSTR®NGMTM PCR Amplification Kit. Results were presented as value of DNA concentrations, mean value of peak heights, mean value of ratio of peak heights and percentage of samples that gave full DNA profile, following standard forensic eligibility criteria. All samples showed average ratio of peak heights for heterozygous loci above 60%, which indicates good DNA profile quality. Isolation, amplification and detection of DNA from cigarette butts and chewing gums (forensic samples) gave better results when using EZ1 workstation. Samples of whole blood showed equally good results using Chelex®100 and EZ1 workstation. Only samples of buccal swabs gave better results with Chelex method. Apart from this, and although future studies with different kinds of samples are needed, all criteria were met and EZ1® Advanced XL instrument with EZ1 Investigator Kit is introduced into our every day casework.

Validation of EZ1® Advanced XL workstation using EZ1 Investigator Kit

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

113-113.

2015.

objavljeno

Podaci o matičnoj publikaciji

International Society for Applied Biological Sciences, Program and Abstracts, 9th ISABS Conference on Forensic, Anthropological Genetics and Mayo Clinic Lectures in Individualized Medicine

Kayser M., Ordog T., Vuk-Pavlović S., Primorac D., Schanfield M.

Zagreb: Grafički zavod Hrvatske

978-953-57695-1-4

Podaci o skupu

9th ISABS Conference on Forensic, Anthropologic Genetics and Mayo Clinic Lectures in Individualized Medicine

poster

01.01.2015-01.01.2015

Bol, Hrvatska

Povezanost rada

Biologija