Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy (CROSBI ID 220888)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Siketić, Zdravko ; Bogdanović Radović, Ivančica ; Jakšić, Milko ; Popović Hadžija, Marijana ; Hadžija, Mirko ; Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy // Applied physics letters, 107 (2015), 093702-1-093702-5. doi: 10.1063/1.4930062

Podaci o odgovornosti

Siketić, Zdravko ; Bogdanović Radović, Ivančica ; Jakšić, Milko ; Popović Hadžija, Marijana ; Hadžija, Mirko ;

engleski

Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

submicron molecular imaging; MeV SIMS; STIM

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

107

2015.

093702-1-093702-5

objavljeno

0003-6951

10.1063/1.4930062

Povezanost rada

Fizika

Poveznice
Indeksiranost