Calculation of No-Load Saturation Curve for Wound Field Synchronous Machines Based on Magnetic Equivalent Circuits and Conformal Mapping (CROSBI ID 627181)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Hanić, Ana ; Hanić, Zlatko ; Vražić, Mario ; Žarko, Damir
engleski
Calculation of No-Load Saturation Curve for Wound Field Synchronous Machines Based on Magnetic Equivalent Circuits and Conformal Mapping
This paper describes a method for calculation of the no-load saturation curve for wound field synchronous machines based on magnetic equivalent circuits and conformal mapping. The method uses conformal mapping to calculate reluctances of the magnetically active parts of the machine which are then used in magnetic equivalent circuit for the calculation of magnetic fluxes. Proposed method is applied to a salient, six-pole, 400 V, 50 Hz synchronous machine with double layered armature winding and obtained results are compared with finite element method.
magnetic equivalent circuits ; conformal mapping ; synchronous machine ; no-load saturation curve
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
1-6.
2015.
nije evidentirano
objavljeno
Podaci o matičnoj publikaciji
Bülent Ertan
Red Hook (NY):
Podaci o skupu
ACEMP-OPTIM-ELECTROMOTION 2015
poster
02.09.2015-04.09.2015
Side, Turska
Povezanost rada
Elektrotehnika