Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Complexation between lysozyme and sodium poly(styrenesulfonate): the effect of pH, reactant concentration and titration direction (CROSBI ID 222935)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Štajner, Lara ; Požar, Josip ; Kovačević, Davor Complexation between lysozyme and sodium poly(styrenesulfonate): the effect of pH, reactant concentration and titration direction // Colloids and surfaces. A, Physicochemical and engineering aspects, 483 (2015), 171-180. doi: 10.1016/j.colsurfa.2015.03.034

Podaci o odgovornosti

Štajner, Lara ; Požar, Josip ; Kovačević, Davor

engleski

Complexation between lysozyme and sodium poly(styrenesulfonate): the effect of pH, reactant concentration and titration direction

It is well-known that mixing of aqueous solutions of oppositely charged proteins and polyelectrolytes leads to the formation of aggregates often called protein-polyelectrolyte complexes. In this study we investigated the interactions between aqueous solutions of lysozyme and sodium poly(styrenesulfonate) (PSS) as the model system for investigating protein-polyelectrolyte complexation processes. The experimental methods used in this study were isothermal titration microcalorimetry, electrophoretic mobility (i.e. zeta potential determination) and particle size (i.e. hydrodynamic radius) measurements. The effect of pH, reactant (protein and polyelectrolyte) concentration and titration direction (addition order) on lysozyme-PSS complexation was investigated at θ = 25 ºC and at ionic strength Ic = 10-2 mol dm-3. At all three examined pH values (pH = 3.1, 4.6 and 7.5) at low charge ratios a stable colloidal suspension was obtained in which charged colloid particles, whose sign of charge corresponds to that of the titrand, were present. On the other hand, at higher charge ratios large particles (floccules) appeared (with the hydrodynamic radius in the range 2 – 7 micrometers). These floccules were also charged and, at first, their charge sign was equal to that of the titrand (│zeta│ = 30 – 50 mV). However, upon further addition of the titrant the charge of the flocculae reversed as a result of the surplus of titrant molecules in the corona. The change in pH leads to the significant change in charge ratios at which the onset of flocculation is observed. In all examined cases the charge ratio at which zeta potential starts to change corresponds to the onset of flocculation determined by DLS. The reaction heat effects were determined and it was shown that in all examined cases complexation resulted in measurable negative enthalpy changes.

Polyelectrolytes ; Sodium poly(styrenesulfonate) ; Lysozyme ; Microcalorimetry ; Dynamic light scattering ; Zeta potential