Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Flow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet (CROSBI ID 227346)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Pavić, Ivica ; Hartmann, Anke ; Zimmerman, Albert ; Michel, Detlef ; Hampl, Walter ; Schleyer, Ingrid ; Mertens, Thomas Flow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet // Antimicrobial agents and chemotherapy, 41 (1997), 12; 2686-2692

Podaci o odgovornosti

Pavić, Ivica ; Hartmann, Anke ; Zimmerman, Albert ; Michel, Detlef ; Hampl, Walter ; Schleyer, Ingrid ; Mertens, Thomas

engleski

Flow cytometric analysis of herpes simplex virus type 1 susceptibility to acyclovir, ganciclovir, and foscarnet

We established a quantitative flow cytometric method for determination of herpes simplex virus type 1 (HSV-1) susceptibility to acyclovir (ACV), ganciclovir, and foscarnet in vitro. Susceptibility was defined in terms of the drug concentration which reduced the number of cells expressing HSV-1 glycoprotein C (gpC) with a fluorescence intensity of > or =10(2) by 50% (IC50). Flow cytometry allowed us to use a high (1.0) as well as a low (0.005) multiplicity of infection, and determination of the IC50 was possible after one or more viral replicative cycles. IC50s were dependent on virus input and on time postinfection. In mixture experiments, 1 to 2% resistant viruses added to a sensitive strain could be detected. The results obtained by flow cytometry showed a good qualitative correlation with those achieved by cytopathic effect inhibitory assay. However, flow cytometry might detect more quantitative differences in drug susceptibility, especially among resistant strains, as confirmed also by determination of intracellular drug phosphorylation. The mean IC50s for ACV-sensitive strains were 0.45 to 1.47 microM, and those for ACV-resistant strains were between 140 and 3, 134 microM. Flow cytometric analysis was fast and accurate, automatizable, and highly reproducible. Flow cytometry may be a more powerful tool than standard cytopathic effect-based assays and could have advantages for the detection of low levels of drug resistance or mixtures of sensitive and resistant virus strains.

Flow cytometry ; HSV ; drug susceptibility

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

41 (12)

1997.

2686-2692

objavljeno

0066-4804

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti, Biologija

Indeksiranost