Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Evaluation of hybrid and non-hybrid methods for de novo assembly of nanopore reads (CROSBI ID 228889)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Sović, Ivan ; Križanović, Krešimir ; Skala, Karolj ; Šikić, Mile Evaluation of hybrid and non-hybrid methods for de novo assembly of nanopore reads // Bioinformatics, 32 (2016), 17; 2582-2589. doi: 10.1093/bioinformatics/btw237

Podaci o odgovornosti

Sović, Ivan ; Križanović, Krešimir ; Skala, Karolj ; Šikić, Mile

engleski

Evaluation of hybrid and non-hybrid methods for de novo assembly of nanopore reads

Motivation: Recent emergence of nanopore sequencing technology set a challenge for established assembly methods. In this work we assessed how existing hybrid and non-hybrid de novo assembly methods perform on long and error prone nanopore reads. Results: We benchmarked five non-hybrid (in terms of both error correction and scaffolding) assembly pipelines as well as two hybrid assemblers which use third generation sequencing data to scaffold Illumina assemblies. Tests were performed on several publicly available MinION and Illumina datasets of E. coli K-12, using several sequencing coverages of nanopore data (20x, 30x, 40x and 50x). We attempted to assess the assembly quality at each of these coverages, in order to estimate the requirements for closed bacterial genome assembly. For the purpose of the benchmark, an extensible genome assembly benchmarking framework was developed. Results show that hybrid methods are highly dependent on the quality of NGS data, but much less on the quality and coverage of nanopore data and perform relatively well on lower nanopore coverages. All non-hybrid methods correctly assemble the E. coli genome when coverage is above 40x, even the non-hybrid method tailored for Pacific Biosciences reads. While it requires higher coverage compared to a method designed particularly for nanopore reads, its running time is significantly lower. Availability: https://github.com/kkrizanovic/NanoMark

nanopore ; sequencing ; de novo

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

32 (17)

2016.

2582-2589

objavljeno

1367-4803

10.1093/bioinformatics/btw237

Povezanost rada

Računarstvo, Biologija

Poveznice
Indeksiranost