Development of the quality assurance/quality control procedures for a neutron interrogation system (CROSBI ID 229106)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Obhođaš, Jasmina ; Sudac, Davorin ; Valković, Vladivoj Development of the quality assurance/quality control procedures for a neutron interrogation system // IEEE transactions on nuclear science, 63 (2016), 3; 1544-1550. doi: 10.1109/TNS.2016.2521900

Podaci o odgovornosti

Obhođaš, Jasmina ; Sudac, Davorin ; Valković, Vladivoj

engleski

Development of the quality assurance/quality control procedures for a neutron interrogation system

In order to perform Quality Assurance/Quality Control (QA/QC) procedures for a system dedicated to the neutron interrogation of objects for the presence of threat materials one needs to perform measurements of reference materials (RM) i.e. simulants having the same (or similar) atomic ratios as real materials. It is well known that explosives, drugs, and various other benign materials, contain chemical elements such as hydrogen, oxygen, carbon and nitrogen in distinctly different quantities. For example, a high carbon-to-oxygen ratio (C/O) is characteristic of drugs. Explosives can be differentiated by measurement of both (C/O) and nitrogen-to-oxygen (N/O) ratios. The C/N ratio of the chemical warfare agents, coupled with the measurement of elements such as fluorine and phosphorus, clearly differentiate them from the conventional explosives. Here we present the RM preparation, calibration procedure and correlations attained between theoretical values and experimentally obtained results in laboratory conditions for C/O and N/C ratios of prepared hexogen (RDX), TNT, DLM2, TATP, cocaine, heroin, yperite, tetranitromethane, peroxide methylethylketone, nitromethane and ethyleneglycol dinitrate simulants. We have shown that analyses of the gamma ray spectra by using simple unfolding model developed for this purpose gave a nice agreement with the chemical formula of created simulants, thus the calibration quality was successfully tested.

Calibration procedures; QA/QC; container inspection; neutron interrogation; threat material analysis; threat material simulants