Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Effect of the pH of Artificial Saliva on Mechanical Properties of Orthodontic Archwires (CROSBI ID 637007)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Katić, Višnja ; Kamenar, Ervin ; Zelenika, Saša ; Marković, Kristina ; Špalj, Stjepan Effect of the pH of Artificial Saliva on Mechanical Properties of Orthodontic Archwires // Abstract book of the IV International Conference on Biodental Engineering. 2016

Podaci o odgovornosti

Katić, Višnja ; Kamenar, Ervin ; Zelenika, Saša ; Marković, Kristina ; Špalj, Stjepan

engleski

Effect of the pH of Artificial Saliva on Mechanical Properties of Orthodontic Archwires

Objectives: To evaluate the effect of surface coating on mechanical properties of orthodontic archwires after corrosion in artificial saliva of different pH values. Materials and Methods: Six samples of three types of orthodontic archwires in dimension 0.020×0.020’’ were tested: uncoated nickel titanium (NiTi), rhodium coated (RhNiTi) and nitrified (NNiTi). Wires were immersed in artificial saliva solution for 28 days and incubated in a water bath at 37°C. The pH values of artificial saliva solutions were adjusted to 4.8 and 6.6. Unexposed wires were used for comparison. Vickers microindentation hardness test was used to analyse the differences in mechanical properties caused by the corrosion. One-way and two-way ANOVA with the Students- Newman-Keuls post-hoc test were used for evaluation of the differences in microhardness between the type of coating and pH value of the media. Results: One-way ANOVA indicates that RhNiTi is harder than the NiTi and NNiTi are (p<0.05). Two-way ANOVA shows that type of coating influences the microhardness (p<0.001 ; η2=0.309), but the pH value has no impact on the microhardness (p=0.237 ; η2=0.070). The combination of the type of coating and the pH value also did not contribute to the change in microhardness (p=0.510 ; η2=0.089). Conclusions: Mechanical properties of orthodontic archwires are influenced by the type of coating but not by the pH value of the artificial saliva.

mechanical properties; orthodontic archwires; artificial saliva

Izrađeno i financirano u sklopu projekta “Imunosne i regenerativne implikacije korozije dentalnih materijala u djece i adolescenata” Hrvatske zaklade za znanost (IP-2014-09-7500) voditelja Stjepana Špalja

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

2016.

objavljeno

Podaci o matičnoj publikaciji

Abstract book of the IV International Conference on Biodental Engineering

Podaci o skupu

IV International Conference on Biodental Engineering

predavanje

21.06.2016-23.06.2016

Porto, Portugal

Povezanost rada

Strojarstvo, Temeljne tehničke znanosti, Dentalna medicina