APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM (CROSBI ID 229911)

Prilog u časopisu | izvorni znanstveni rad

Milovančević, Miloš ; Vračar, Ljubomir ; Troha, Sanjin APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM // Machine Design (Novi Sad), 7 (2015), 3; 97-100

Podaci o odgovornosti

Milovančević, Miloš ; Vračar, Ljubomir ; Troha, Sanjin

engleski

APPLICABLE IMPORTANCE OF VIBRO_DIAGNOSTICS IN PREDICTABLE MAINTENANCE OF "NAISUS" AQUEDUCT SYSTEM

In order to secure the working order of mechanical systems, it is necessary to ensure a variety of supervision measures of working reliability. Basis of this control are supervision of vibrations and their measuring by electric devices. "Naissus" waterworks with its wells, intake system, adequate distribution and manifold network, pumping stations and water reservoirs - all represents the Nish Aqueduct System (NIVOS). It supplies with fresh water about 240000 people and very diverse industry of Nish municipality with 103377 cubic meters per day, making it 37732608 cubic meters per year. Important part of this complex system of water distribution to consumers is about fifty functional pumping stations. These pumping stations contain 115 pumping power units with different assignments. Use of vibrodiagnostics to provide predictable maintanance is a key segment in realization of the flawless work of pumping power units.

water distribution; vibrodiagnostics; pumping power units