Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

I2S-LWR Activation Analysis of Heat Exchangers Using Hybrid Shielding Methodology With SCALE6.1 (CROSBI ID 637674)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Matijević, Mario ; Pevec, Dubravko ; Ječmenica, Radomir I2S-LWR Activation Analysis of Heat Exchangers Using Hybrid Shielding Methodology With SCALE6.1 // 11th International Conference of the Croatian Nuclear Society Proceedings / Šimić, Zdenko ; Tomšić, Željko ; Grgić, Davor (ur.). Zagreb: Hrvatsko nuklearno društvo, 2016. str. 64-1-64-12

Podaci o odgovornosti

Matijević, Mario ; Pevec, Dubravko ; Ječmenica, Radomir

engleski

I2S-LWR Activation Analysis of Heat Exchangers Using Hybrid Shielding Methodology With SCALE6.1

The Integral Inherently Safe Light Water Reactor (I2S-LWR) concept developed by Georgia Tech is a novel PWR reactor delivering electric power of 1000 MWe while implementing inherent safety features typical for Generation III+ small modular reactors. The main safety feature is based on integral primary circuit configuration, bringing together compact design of the reactor core with 121 fuel assembly (FA), control rod drive mechanism (CRDM), 8 primary heat exchangers (PHE), 4 passive decay heat removal systems (DHRS), 8 pumps, and other integral components. A high power density core based on silicide fuel is selected to achieve a high thermal power which is extracted with PHEs placed in the annual region between the barrel and the vessel. The complex and integrated design of I2S-LWR leads to activation of integral components, mainly made from stainless steel, so accurate and precise Monte Carlo (MC) simulations are needed to quantify potential dose rates to personnel during routine maintenance operation. This shielding problem is therefore very challenging one, posing a non-trivial neutron flux solution in a phase space. This paper presents the performance of the hybrid shielding methodologies CADIS/FW-CADIS implemented in the MAVRIC sequence of the SCALE6.1 code package. The main objective was to develop a detailed MC shielding model of the I2S-LWR reactor along with effective variance reduction (VR) parameters and to calculate neutron fluence rates inside PHEs. Such results are then utilized to find neutron activation rate distribution via 60Co generation inside of a stack of microchannel heat exchangers (MCHX), which will be periodically withdrawn for the maintenance. 59Co impurities are the main cause of (n, γ) radiative gamma dose to personnel via neutron activation since 60Co has half-life of 5.27 years and is emitting high energy gamma rays (1.17 MeV and 1.33 MeV). The developed MC model was successfully used to find converged fluxes inside all 8 stacks of PHEs with respect to MC statistics using FW-CADIS methodology. For that purpose the SN module Denovo, based on forward-adjoint transport theory, was used to find VR parameters (importance map and biased source) to effectively bias MC simulation. Further research is required to account for other activation pathways, i.e. isotopes of iron which may generate 59Co through neutron activation and beta decay.

: I2S-LWR; PWR; shielding; Monte Carlo; activation; SCALE6.1; FW-CADIS

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

64-1-64-12.

2016.

objavljeno

Podaci o matičnoj publikaciji

Šimić, Zdenko ; Tomšić, Željko ; Grgić, Davor

Zagreb: Hrvatsko nuklearno društvo

978-953-55224-8-5

Podaci o skupu

11th International Conference of the Croatian Nuclear Society

predavanje

05.06.2016-08.06.2016

Zadar, Hrvatska

Povezanost rada

Elektrotehnika