Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Benefits of selective peptide derivatization with sulfonating reagent at acidic pH for facile matrix- assisted laser desorption/ionization de novo sequencing (CROSBI ID 230629)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Butorac, Ana ; Solak Mekić, Meliha ; Hozić, Amela ; Diminić, Janko ; Gamberger, Dragan ; Nišavić, Marija ; Cindrić, Mario Benefits of selective peptide derivatization with sulfonating reagent at acidic pH for facile matrix- assisted laser desorption/ionization de novo sequencing // RCM. Rapid communications in mass spectrometry, 30 (2016), 14; 1687-1694. doi: 10.1002/rcm.7594

Podaci o odgovornosti

Butorac, Ana ; Solak Mekić, Meliha ; Hozić, Amela ; Diminić, Janko ; Gamberger, Dragan ; Nišavić, Marija ; Cindrić, Mario

engleski

Benefits of selective peptide derivatization with sulfonating reagent at acidic pH for facile matrix- assisted laser desorption/ionization de novo sequencing

RATIONALE One of the most challenging tasks of proteomics is peptide de novo sequencing. 4- Sulfophenyl isothiocyanate (SPITC) peptide derivatization enables acquisition of high- quality tandem mass spectra (MS/MS) for de novo sequencing, but unwanted non-specific reactions and reduced mass spectra (MS) signal intensities still represent the obstacles in high-throughput de novo sequencing. METHODS We developed a SPITC peptide derivatization procedure under acidic conditions (pH ≤5). Derivatized peptides were analyzed by matrix- assisted laser desorption/ionization (MALDI-MS) in negative ion mode followed by MS/MS in positive ion mode. A de novo sequencing tool, named DUST, adjusted to SPITC chemistry, was designed for successful high-throughput peptide de novo sequencing. This high-throughput peptide de novo sequencing was tested on Fusarium delphinoides, an organism with an uncharacterized genome. RESULTS The SPITC derivatization procedure under acidic conditions produced a significantly improved MS dataset in comparison to commonly used derivatization under basic conditions. Signal intensities were 6 to 10 times greater and the over-sulfonation effect measured on lysine- containing peptides was significantly decreased. Furthermore, development of a novel DUST algorithm enabled automated de novo sequencing with the calculated accuracy of 70.6%. CONCLUSIONS The SPITC derivatization and de novo sequencing approach outlined here provides a reliable method for high-throughput peptide de novo sequencing. High-throughput peptide de novo sequencing enabled protein mutation identification and identification of proteins from organisms with non-sequenced genomes.

de novo sequencing ; peptide derivatization ; MALDI-TOF/TOF

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

30 (14)

2016.

1687-1694

objavljeno

0951-4198

1097-0231

10.1002/rcm.7594

Povezanost rada

Kemija

Poveznice
Indeksiranost