Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Design and calculation of cylindrical industrial air filter device with use of CFD analysis (CROSBI ID 640699)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Mandic, M. ; Kozak, D. ; Gelo, I. ; Holik, M. Design and calculation of cylindrical industrial air filter device with use of CFD analysis // Proceedings of the 8th International Scientific and Expert Conference TEAM 2016 / Maronek, Milan ; Barta Jozef (ur.). Trnava: Alumni Press, 2016. str. 124-135

Podaci o odgovornosti

Mandic, M. ; Kozak, D. ; Gelo, I. ; Holik, M.

engleski

Design and calculation of cylindrical industrial air filter device with use of CFD analysis

In order to reduce emissions and improve the quality of ambient air or air in the working space it is necessary to clean emission particles. Air purity is achieved by proper filtration process of emission particles. In this paper housing of cylindrical industrial air filter device was designed and optimized with the use of CFD analysis. Model of cylindrical filter device was made in the software SolidWorks Premium 2016. Several models of product were made until satisfactory design from the perspective of functional and technological feasibility was reached. Furthermore, multi physical analysis was conducted in software ANSYS Workbench. CFD analysis of fluid flow was carried out using software ANSYS CFX. Based on CFD analysis of fluid flow and distribution of pressure on filter device wall, analysis of strength was conducted in ANSYS Static Structural, and model optimization in ANSYS DesignXplorer. Optimized model serves as an orientation model for further analysis of critical loads (underpressure, overpressure). Optimized model strength analysis at working pressure with value of -1277.6 Pa show that maximum equivalent stress is 114.03 MPa. In the condition of high value of overpressure with value of 1059.43 Pa maximum equivalent stress is 378.09 MPa, and for high value of underpressure with value of -5936.6 Pa maximum equivalent stress is 534.91 MPa. Optimized model requires further work in order to reduce stresses in the case of critical loads. This paper presents a coupling of CAD and CAE technologies in process of new product development.

Design; Filtering device; CFD analysis; Strength; Optimization

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

124-135.

2016.

objavljeno

Podaci o matičnoj publikaciji

Proceedings of the 8th International Scientific and Expert Conference TEAM 2016

Maronek, Milan ; Barta Jozef

Trnava: Alumni Press

978-80-8096-237-1

Podaci o skupu

8th International Scientific and Expert Conference TEAM 2016

poster

19.10.2016-21.10.2016

Slovačka

Povezanost rada

Strojarstvo