Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration (CROSBI ID 465271)
Prilog sa skupa u zborniku | izvorni znanstveni rad
Podaci o odgovornosti
Bajs, Tomislav ; Krajnc, Božidar
engleski
Assessment of LOCA Calculation for NEK IPE Level1/Level2 Integration
Medium break loss of coolant accident is in probabilistic safety analysis typically defined as break size for which high pressure injection system with single failure criteria is sufficient to mitigate consequences of the accident, e.g. to maintain rod temperatures bellow damage criteria. Consequently, break sizes for whose mitigation low pressure injection system is essential, are assumed to fall in large break loss of coolant category. In this report, best-estimate thermohydraulic code RELAP5/mod2 has been used to determine the role of accumulators on the system response for different break sizes. Outcome of the analysis has shown that most severe break sizes, with respect to the rod temperature are: 5 in equivalent break size for medium break and 12 in equivalent break size for large break. The results of RELAP5/mod2 analysis have been compared with MAAP results from NEK (Nuklearna Elektrana Krško) IPE (Individual Plant Examination) level1/level2 integration and major differences in the results were discussed.
NPP safety; medium break loss of coolant accident; accumulators
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
478-487-x.
1996.
objavljeno
Podaci o matičnoj publikaciji
Nuclear Option in Countries with Small and Medium Electricity Grid
Knapp, Vladimir ; Čavlina, Nikola
Hrvatsko nuklearno društvo
Podaci o skupu
International Conference: Nuclear Option in Countries with Small and Medium Electricity Grid
poster
07.10.1996-09.10.1996
Opatija, Hrvatska