Comparison of boilers for treated and untreated waste (CROSBI ID 641276)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Janda, Martin ; Dlouhy, Tomas ; Blecich, Paolo ; Franković, Bernard
engleski
Comparison of boilers for treated and untreated waste
This paper presents the design and comparison of two boilers with the same steam output, but with different quality of incoming fuel. The first steam boiler is fed by low quality municipal waste without any treatment, which has a lower calorific value of 9.2 MJ/kg. In contrast to the first fuel, the second fuel is a sorted municipal waste with a lower calorific value of 16.3 MJ/kg. For the sizing of boilers, the same methodology of calculation is used, which ensures the comparability of these projects. The comparison includes the analysis of the fuel quantity supplied to the boilers, the size of the boilers and the combustion conditions.
municipal waste; sorted waste; waste incinerator; steam boiler; lower calorific value; pretreatment of waste
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
59-68.
2016.
objavljeno
Podaci o matičnoj publikaciji
Franković, Bernard
Rijeka: Hrvatski savez za sunčevu energiju
978-953-6886-23-4
Podaci o skupu
International Congress Energy and the Environment 2016
predavanje
26.10.2016-28.10.2016
Opatija, Hrvatska