Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Evaluation of ELISA for the detection of rabies virus antibodies from the thoracic liquid and muscle extract samples in the monitoring of fox oral vaccination campaigns (CROSBI ID 234346)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bedeković, Tomislav ; Šimić, Ivana ; Krešić, Nina ; Lojkić, Ivana ; Mihaljević, Željko ; Sučec, Ivica ; Lohman Janković, Ivana ; Hostnik, Peter Evaluation of ELISA for the detection of rabies virus antibodies from the thoracic liquid and muscle extract samples in the monitoring of fox oral vaccination campaigns // BMC Veterinary Research, 12 (2016), 76; 1-7. doi: 10.1186/s12917-016-0701-0

Podaci o odgovornosti

Bedeković, Tomislav ; Šimić, Ivana ; Krešić, Nina ; Lojkić, Ivana ; Mihaljević, Željko ; Sučec, Ivica ; Lohman Janković, Ivana ; Hostnik, Peter

engleski

Evaluation of ELISA for the detection of rabies virus antibodies from the thoracic liquid and muscle extract samples in the monitoring of fox oral vaccination campaigns

Background: The main goal of oral vaccination of foxes is eradication of rabies in the red fox population as rabies reservoirs. To evaluate the success of vaccination a serological testing is conducted as a part of monitoring program. Two different methods are used regarding rabies serology: virus neutralisation test and ELISA. Methods: In this study the reliability of BioPro ELISA was evaluated for testing haemolytic thoracic liquids and muscle extracts originated from 147 foxes in comparison to mFAVN. Also, the influence of heat treatment of samples on test results was investigated. Results: The specificity of the test for not-heat treated samples was 92.98 % and sensitivity 79.20 %. Diagnostic validity of the ELISA compared to the mFAVN test when not-heat treated samples were used was 89.16 %. The specificity of the test for heat treated samples was 79.10 % and sensitivity 96.36 %. Diagnostic validity of the BioPro ELISA compared to the mFAVN test for heat treated samples was 94.30 %. Conclusion: According to this study, the BioPro ELISA is reliable tool for detection of rabies specific antibodies in the context of evaluation of oral vaccination of foxes from poor quality samples as a substitution for virus neutralisation tests.

BioPro ELISA ; Muscle extract ; Thoracic liquid ; Evaluation

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

12 (76)

2016.

1-7

objavljeno

1746-6148

10.1186/s12917-016-0701-0

Povezanost rada

Veterinarska medicina

Poveznice
Indeksiranost