Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Out-of-plane behaviour of framed-masonry walls with opening as a result of shaking table tests (CROSBI ID 643873)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Penava, Davorin ; Sigmund, Vladimir Out-of-plane behaviour of framed-masonry walls with opening as a result of shaking table tests // Proceedings of the 16th World Conference on Earthquake Engineering / Chilean Association of Seismology and Earthquake Engineering Board Directors ACHISINA – Asociación Chilena de Sismología e Ingeniería Antisísmica (ur.). Santiago: Chilean Association of Seismology and Earthquake Engineering Board Directors ACHISINA – Asociación Chilena de Sismología e Ingeniería Antisísmica, 2017. str. 1-9

Podaci o odgovornosti

Penava, Davorin ; Sigmund, Vladimir

engleski

Out-of-plane behaviour of framed-masonry walls with opening as a result of shaking table tests

Reinforced concrete frame structure infilled with masonry walls was built in a scale 1/2.5 and tested on shaking table under earthquake excitation. It consisted of three storeys with two longitudinal frames in the direction of earthquake excitation and three transverse bays perpendicular to the direction of earthquake excitation. The both longitudinal and central transverse reinforced concrete frames were infilled with masonry walls throughout the entire height of the structure. The masonry walls were made of clay block masonry units and masonry mortar. The structure model was excited in sequences with increasing earthquake peak acceleration by each sequence. Observed were masonry walls placed in the central transverse bay that were exposed to the out-of-plane excitation. They had door opening in the ground floor and window openings in the first and the second floor. The existing simplified model to verify the out of plane resistance of complete masonry walls without openings was applied before the tests. As the tests revealed, they incorrectly estimated their resistance since different failure mechanisms occurred. Position of the failed infilled masonry wall with opening and its failure mechanisms were opposite to the current perceptions for out-of-plane infilled walls behaviour. Detailed description of observed behaviour and measures that could be used for improvement of their behaviour under earthquake excitation is presented.

out-of-plane behaviour ; framed-masonry ; openings ; shaking table tests

Registration Code: S-O1463034437

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1-9.

2017.

objavljeno

Podaci o matičnoj publikaciji

Chilean Association of Seismology and Earthquake Engineering Board Directors ACHISINA – Asociación Chilena de Sismología e Ingeniería Antisísmica

Santiago: Chilean Association of Seismology and Earthquake Engineering Board Directors ACHISINA – Asociación Chilena de Sismología e Ingeniería Antisísmica

Podaci o skupu

16th World Conference on Earthquake Engineering

poster

09.01.2017-13.01.2017

Santiago, Čile

Povezanost rada

Građevinarstvo