Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. (CROSBI ID 236348)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Nikolac, Nora ; Leniček Krleža, Jasna ; Šimundić, Ana- Maria Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots. // Biochemia medica, 27 (2017), 1; 131-143. doi: 10.11613/BM.2017.017

Podaci o odgovornosti

Nikolac, Nora ; Leniček Krleža, Jasna ; Šimundić, Ana- Maria

engleski

Preanalytical external quality assessment of the Croatian Society of Medical Biochemistry and Laboratory Medicine and CROQALM: finding undetected weak spots.

Introduction: The aim of this paper is to present results of first two years of preanalytical external quality assessment (EQA) in Croatia. Materials and methods: This paper summarizes results from 6 rounds of preanalytical EQA during 2014-2016 in 161-175 Croatian laboratories (number ranged between cycles). EQA was designed as an online survey of the compliance with National recommendations for phlebotomy (NRP). Forty-seven questions in 5 categories are analyzed (materials and equipment, patient identification, patient preparation, sampling and storage). Additionally, preanalytical cases are presented. Overall performance scores (Question score (Qscore) for compliance with NRP and Case score (Cscore) for preanalytical cases) are calculated for each question/case as a proportion of laboratories with satisfactory procedure (x 100). Qscores and Cscores ≥ 70 were classified as acceptable (maximal score = 100). Results: In investigation of compliance with NRP, acceptable Qscores were obtained for 34/47 questions. The lowest scores were observed for the availability of sterile disposable tourniquets (Qscore = 15) and safe- sharp needles (Qscore = 34), obtaining patients address as an identifier (Qscore = 21), using glycolysis inhibitor tubes for glucose concentration measurement (Qscore = 21) and verification of manufacturers declarations on temperature and time of storage (Qscore = 31). There was no statistically significant difference in overall Qscore according to different categories of phlebotomy procedures (P = 0.284). The results of preanalytical cases showed acceptable Cscore values for all cases (89-96). Conclusion: First two years of preanalytical EQA showed good compliance with the NRP and excellent expertise in resolving complex preanalytical issues. Major critical spots are lack of availability of safe-sharp needles, disposable tourniquets and glucose inhibitor tubes.

Preanalytical phase ; External quality assessment ; Laboratory error

S.I.: External Quality Assessment in Laboratory Medicine.

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

27 (1)

2017.

131-143

objavljeno

1330-0962

10.11613/BM.2017.017

Povezanost rada

Temeljne medicinske znanosti, Kliničke medicinske znanosti, Javno zdravstvo i zdravstvena zaštita

Poveznice
Indeksiranost