Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Quantitative analysis of endocytic recycling of membrane proteins by monoclonal antibody-based recycling assays (CROSBI ID 240289)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Blagojević Zagorac, Gordana ; Mahmutefendić, Hana ; Maćešić, Senka ; Karleuša, Ljerka ; Lučin, Pero Quantitative analysis of endocytic recycling of membrane proteins by monoclonal antibody-based recycling assays // Journal of cellular physiology, 232 (2017), 3; 463-476. doi: 10.1002/jcp.25503

Podaci o odgovornosti

Blagojević Zagorac, Gordana ; Mahmutefendić, Hana ; Maćešić, Senka ; Karleuša, Ljerka ; Lučin, Pero

engleski

Quantitative analysis of endocytic recycling of membrane proteins by monoclonal antibody-based recycling assays

In this report, we present an analysis of several recycling protocols based on labeling of membrane proteins with specific monoclonal antibodies (mAbs). We analyzed recycling of membrane proteins that are internalized by clathrin-dependent endocytosis, represented by the transferrin receptor, and by clathrin-independent endocytosis, represented by the Major Histocompatibility Class I molecules. Cell surface membrane proteins were labeled with mAbs and recycling of mAb:protein complexes was determined by several approaches. Our study demonstrates that direct and indirect detection of recycled mAb:protein complexes at the cell surface underestimate the recycling pool, especially for clathrin-dependent membrane proteins that are rapidly reinternalized after recycling. Recycling protocols based on the capture of recycled mAb:protein complexes require the use of the Alexa Fluor 488 conjugated secondary antibodies or FITC-conjugated secondary antibodies in combination with inhibitors of endosomal acidification and degradation. Finally, protocols based on the capture of recycled proteins that are labeled with Alexa Fluor 488 conjugated primary antibodies and quenching of fluorescence by the anti-Alexa Fluor 488 displayed the same quantitative assessment of recycling as the antibody-capture protocols.

Endosomal recycling ; Recycling protocols ; Monoclonal antibodies ; MHC Class I recycling ; Transferrin receptor recycling

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

232 (3)

2017.

463-476

objavljeno

0021-9541

10.1002/jcp.25503

Povezanost rada

Temeljne medicinske znanosti

Poveznice
Indeksiranost