FEM analysis of single-phase electromechanical meter-Impact of harmonics
In this paper, different analytical calculation methods of active and reactive power, for loads with a presence of harmonics, was compared with calculations provided through FEM analysis of the single-phase electromechanical electricity meters based on the principle of Ferraris energy meter. For validation was used standardized voltage and current signals with the strong impact of harmonics, i.e. realistic measurements for non- sinusoidal power supply as result of high- frequency switch-mode power conversion technology.
FEM analisys, non-sinusoidal power supply, impact of harmonics, Ferraris energy meter
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
57-57.
2017.
objavljeno
Podaci o matičnoj publikaciji
XIX International Symposium on Theoretical Electrical Engineering
Scharff, Peter
Ilmenau: Technische Universitat Ilmenau
Podaci o skupu
XIX International Symposium on Theoretical Electrical Engineering ISTET 2017
predavanje
16.07.2017-19.07.2017