Gas or plasma jet: Targets for Laser Induced Breakdown Spectroscopy (CROSBI ID 651575)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Popović, Dean ; Bišćan, Marijan ; Šegedin, Nikola ; Milošević, Slobodan Gas or plasma jet: Targets for Laser Induced Breakdown Spectroscopy // 7th Central European Symposium on Plasma Chemistry, Scientific Program and Book of Abstracts / Milošević, Slobodan ; Krstulović, Nikša (ur.). Zagreb: Institut za fiziku, 2017. str. 118-118

Podaci o odgovornosti

Popović, Dean ; Bišćan, Marijan ; Šegedin, Nikola ; Milošević, Slobodan

engleski

Gas or plasma jet: Targets for Laser Induced Breakdown Spectroscopy

In our work, we have investigated the difference between using a gas target or a plasma jet as a target for Laser Induced Breakdown Spectroscopy. Laser plasma was produced by focusing the Nd:YaG laser pulse (4-5 ns pulse duration) either into the gas target or plasma jet. The plasma jet was generated by using either sinusoidal-like or pulsed-DC high voltage with frequency around 25 or 10 kHz respectively. Shielding gas was implemented in the experimental setup to reduce the interaction between helium metastables and nitrogen molecules and enable diagnostics. Since both types of plasma evolve in time very fast, time-resolved spectroscopy was used as a main diagnostical method. For this purpose light that the plasmas emit was collected with optical fibre from focal region to monochromator. After passing the monochromator’s exit slit, the light was detected with photomultiplier tube and the signal recorded on the computer. From the measured spectral line profiles we determined the electron temperatures and concentrations for different time windows. Interesting observation was the decrease in He (388.86 nm) emission line intensity when the laser was focused into the plasma jet, compared to the case where only the gas target was used. This is because of the reabsorption of the emitted light on the efficiently produced helium metastables in the plasma jet.

Laser induced breakdown, atmospheric pressure plasma jet, time-resolved optical emission spectroscopy

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

118-118.

2017.

objavljeno

Podaci o matičnoj publikaciji

7th Central European Symposium on Plasma Chemistry, Scientific Program and Book of Abstracts

Milošević, Slobodan ; Krstulović, Nikša

Zagreb: Institut za fiziku

978-953-7666-16-3

Podaci o skupu

7th Central European Symposium on Plasma Chemistry, CESPC-7

poster

03.09.2017-07.09.2017

Sveti Martin na Muri, Hrvatska

Povezanost rada

Fizika