Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Growth defects in magnetron sputtered PVD flims deposited in UHV environment (CROSBI ID 245563)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Čekada, Miha ; Radić, Nikola ; Jerčinović, Marko ; Panjan, Matjaž ; Panjan, Peter ; Drnovšek, Aljaz ; Car, Tihomir Growth defects in magnetron sputtered PVD flims deposited in UHV environment // Vacuum, 138 (2017), 213-217. doi: 10.1016/j.vacuum.2016.12.012

Podaci o odgovornosti

Čekada, Miha ; Radić, Nikola ; Jerčinović, Marko ; Panjan, Matjaž ; Panjan, Peter ; Drnovšek, Aljaz ; Car, Tihomir

engleski

Growth defects in magnetron sputtered PVD flims deposited in UHV environment

The growth defects in magnetron sputtered coatings have been well studied in industrial environment. In this work, on the other hand, the emphasis is in observing the same phenomena in a lab-scale UHV environment. TiN and CrN films were deposited at a thickness of 1-2 mu m. The statistical evaluation of defect density was based on stylus profilometry scans (2 mm(2) area), and consequent analysis of hillock density in dependence of threshold height. Morphology of defects was observed by SEM, while on selected defects we made FIB cross-sections. In this way we were able to measure the chemical composition of individual seeds - starting points for growth defects. In contrast to expectations, there was only a relatively minor reduction of defect density by using UHV environment. (C) 2016 Elsevier Ltd. All rights reserved.

Growth defects ; Magnetron sputtering ; TiN ; CrN

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

138

2017.

213-217

objavljeno

0042-207X

10.1016/j.vacuum.2016.12.012

Povezanost rada

Fizika

Poveznice
Indeksiranost