Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Comparison of different methodologies for the 90 Sr determination in environmental samples (CROSBI ID 245910)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Grahek, Željko ; Dulanská, Silvia ; Karanović, Gorana ; Coha, Ivana ; Tucaković, Ivana ; Nodilo, Marijana ; Mátel, Ľubomír Comparison of different methodologies for the 90 Sr determination in environmental samples // Journal of environmental radioactivity, 181 (2018), 18-31. doi: 10.1016/j.jenvrad.2017.10.012

Podaci o odgovornosti

Grahek, Željko ; Dulanská, Silvia ; Karanović, Gorana ; Coha, Ivana ; Tucaković, Ivana ; Nodilo, Marijana ; Mátel, Ľubomír

engleski

Comparison of different methodologies for the 90 Sr determination in environmental samples

The paper describes different isolation/separation and detection procedures for 90Sr determination in the environmental samples which are routinely used in Laboratories A and B. In this context, four different methods for strontium isolation and two methods for detection were tested and compared by 90Sr determination in proficiency test samples (water, soil, vegetation) and animal bone samples. The chromatographic isolation of Sr on Sr resin, AnaLigSr01 resin gel, strong base anion exchange resins in nitrate form and combination of strong base anion exchange and Sr resin were used for the examination of the impact of sample matrix constituents on efficiency of strontium isolation (chemical yield), while Cherenkov counting of 90Y and counting of 90Sr(90Y) on proportional counter were used for the quantitative 90Sr determination. The chemical yields obtained with different isolation methods were compared with the emphasis on its influence on reliability of the 90Sr determination in different kinds of samples. The results show that the efficiency of strontium isolation depends on type of sample and separation methodology. The strontium yield on Sr resin column decreases with the increase of Sr, Ca and Na concentration. In the presence of 1g of Ca and 1g of Na, the yield of 85% was obtained for 5mg of Sr carrier and dropped below 50% with further increase of Sr and other elements. However, the yield can be increased to 75% if Na and part of Ca are separated from Sr on the anion exchange column with alcoholic solution of nitric acid and by final separation of Ca from Sr on the Sr resin column. In the presence of large amounts of Ca, Na and other elements, isolation efficiency on the Sr resin column significantly decreases in comparison with other methods. The average yield for isolation from vegetation samples on the Sr resin column is only 21%. For the soil samples the highest average yield (78%) is obtained for the isolation in the combination of anion exchange and Sr resin columns. For the isolation from bone samples the average yields over 80% are on AnaLigSr01 and anion exchange resins columns, while Sr resin was not used for separation due to high content of Ca in samples. The results of the 90Sr determination in proficiency testing (PT) samples show that the accuracy of the determination does not depend on high chemical yield but depends on accuracy of yield determination. The analysis of z-values shows that 96% of obtained z-values range from 0 to ±2 while 77% of z-values range between 0 and±1. Ninety percent of obtained results of 90Sr determination deviate less than 20% from assigned values in PT provider reports. The results of 90Sr determination in animal bone samples using different methods are in good agreement. The results obtained by Cherenkov counting in both laboratories vary from -3.1-14.5% while results obtained by determination via 90Y and counting on i-Matic vary between -10.0 and -2.9%. These deviations are in accordance with deviations obtained with PT samples. Activity concentrations of 90Sr in wild boar bone samples range from 4 to 30 Bq kg-1 while in deer bone samples from 2 to 8 Bq kg-1.

AnaLig()Sr01 ; animal bone samples ; separation ; Sr resin ; strontium ; yield

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

181

2018.

18-31

objavljeno

0265-931X

1879-1700

10.1016/j.jenvrad.2017.10.012

Povezanost rada

Interdisciplinarne prirodne znanosti, Kemija, Kemijsko inženjerstvo

Poveznice
Indeksiranost