Structural analysis of a steel column exposed to a localized fire (CROSBI ID 245996)

Prilog u časopisu | izvorni znanstveni rad | domaća recenzija

Faldić, Tonko ; Craveiro, Helder ; Santiago, Aldina ; Torić, Neno Structural analysis of a steel column exposed to a localized fire // Electronic journal of the Faculty of Civil Engineering Osijek - e-GFOS, 15 (2017), 4; 1-12. doi: 10.13167/2017.15.1

Podaci o odgovornosti

Faldić, Tonko ; Craveiro, Helder ; Santiago, Aldina ; Torić, Neno

engleski

Structural analysis of a steel column exposed to a localized fire

This paper presents an investigation on the structural analysis of a steel column exposed to a localized fire. Because EN 1991-1-2 does not provide a simplified method to calculate heat transfer to vertical elements, a CFD (Computational Fluid Dynamics) model of a localized fire is developed, based on previously conducted experiments. Furthermore, a heat transfer analysis was performed based on the results of CFD modeling and for the ISO temperature–time curve. Finally, a nonlinear structural analysis of the steel column was conducted for the localized fire scenario, as well as for the ISO temperature–time curve. A comparison between the localized fire and ISO fire exposure points indicates that localized fires can cause earlier failure of a column, depending on the level of external load.

fire modeling ; localized fire ; heat transfer ; structural analysis ; nonlinear analysis ; steel