Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

Characterization of the SIDDHARTA-2 second level trigger detector prototype based on scintillators coupled to a prism reflector light guide (CROSBI ID 250761)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Bazzi, M. ; Berucci, C. ; Curceanu, C. ; d’Uffizi, A. ; Iliescu, M. ; Sbardella, E. ; Scordo, A. ; Shi, H. ; Sirghi, F. ; Tatsuno, H. et al. Characterization of the SIDDHARTA-2 second level trigger detector prototype based on scintillators coupled to a prism reflector light guide // Journal of Instrumentation, 8 (2013), T11003, 13. doi: 10.1088/1748-0221/8/11/T11003

Podaci o odgovornosti

Bazzi, M. ; Berucci, C. ; Curceanu, C. ; d’Uffizi, A. ; Iliescu, M. ; Sbardella, E. ; Scordo, A. ; Shi, H. ; Sirghi, F. ; Tatsuno, H. ; Tucaković, Ivana

engleski

Characterization of the SIDDHARTA-2 second level trigger detector prototype based on scintillators coupled to a prism reflector light guide

The SIDDHARTA experiment at the DAΦNE collider of LNF-INFN performed in 2009 high precision measurements of kaonic hydrogen and kaonic helium atomic transitions. To determine the KN isospin dependent scattering lenghts an important measurement, namely the kaonic deuterium one, is, however, still missing. Due to the very low expected yield of the kaonic deuterium Kα transition, a major improvement in the signal over background ratio is needed. To achieve a further background reduction, a second level trigger, based on the detection of charged pions produced by the K^− absorption on various materials, including the target gas nuclei, is planned to be implemented in the future SIDDHARTA-2 experiment. For shielding-related geometrical limitations, a single side of the scintillators can be accessed ; in order to reach a good time resolution and uniform efficiency, a both- end readout was then realized with complex multi-reflection light guides. In this work, the results of the tests made on a detector prototype, performed on the πM−1 beamline of the Paul Scherrer Institute (Switzerland), are presented. The tests had the goal to determine the efficiency and the time resolution for pions, which should comply with the minimum required values of 90% and 1 ns (FWHM) respectively. The obtained results, 96% efficiency and 750 ps FWHM for 170 MeV/c momentum pions, qualify the prototype as an excellent second level trigger for the SIDDHARTA-2 experiment. Similar results for 170 MeV/c momentum muons and electrons are also presented.

Trigger concepts and systems (hardware and software) ; Scintillators, scintillation and light emission processes (solid, gas and liquid scintillators) ; Scintillators and scintillating fibres and light guides ; Trigger detectors

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

8

2013.

T11003

13

objavljeno

1748-0221

10.1088/1748-0221/8/11/T11003

Povezanost rada

Fizika

Poveznice
Indeksiranost