AC-DC transfer difference measurement of AC shunts (CROSBI ID 661575)
Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Konjevod, Jure ; Dadić, Martin ; Malarić, Roman ; Kunšt, Ivica
engleski
AC-DC transfer difference measurement of AC shunts
The paper describes the ac-dc transfer difference measurement of six cage type ac shunts from 10 mA up to 10 A recently developed at the Faculty of electrical engineering and computing, University of Zagreb (UNIZG-FER). The shunts have been measured using step-up measurement procedure. Thus, two planar multijunction thermal converters (PMJTCs) are used. Ac-dc transfer of a PMJTC is taken as reference in the first step of step-up procedure. Ac-dc transfer difference of all shunts has been determined to be less than 20 µΩ/Ω under 10 kHz, while ac-dc difference for shunts in frequency range 20-100 kHz varies about few hundreds µΩ/Ω.
Current shunts, AC-DC transfer difference, step-up procedure, PMJTC
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o prilogu
83-86.
2018.
objavljeno
Podaci o matičnoj publikaciji
Proceedings of First International Colloquium on Smart Grid Metrology 2018 (SMAGRIMET 2018)
Ivšić, Branimir ; Jurčević, Marko
Zagreb: Fakultet elektrotehnike i računarstva Sveučilišta u Zagrebu
978-953-184-234-1
Podaci o skupu
First International Colloquium on Smart Grid Metrology (SmaGriMet 2018)
poster
24.04.2018-27.04.2018
Split, Hrvatska