Advantageous environment of micro-patterned, high-density complementary metal-oxide-semiconductor electrode array for spiral ganglion neurons cultured in vitro (CROSBI ID 252514)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Radotić, Viktorija ; Braeken, Dries ; Drviš, Petar ; Mattotti, Marta ; Kovačić, Damir Advantageous environment of micro-patterned, high-density complementary metal-oxide-semiconductor electrode array for spiral ganglion neurons cultured in vitro // Scientific reports, 8 (2018), 7446, 19. doi: 10.1038/s41598-018-25814-w

Podaci o odgovornosti

Radotić, Viktorija ; Braeken, Dries ; Drviš, Petar ; Mattotti, Marta ; Kovačić, Damir

engleski

Advantageous environment of micro-patterned, high-density complementary metal-oxide-semiconductor electrode array for spiral ganglion neurons cultured in vitro

This study investigated micro-patterned, high- density complementary metal–oxide–semiconductor (CMOS) electrode array to be used as biologically permissive environment for organization, guidance and electrical stimulation of spiral ganglion neurons (SGN). SGNs extracted and isolated from cochleae of P5- P7 rat pups and adult guinea pigs were cultured 1, 4 and 7 days in vitro on glass coverslips (control) and CMOS electrode array. The cultures were analyzed visually and immunohistochemically for SGN presence, outgrowth, neurite alignment, neurite length, neurite asymmetry as well as the contact of a neuronal soma and neurites with the micro- electrodes. Our findings indicate that topographical environment of CMOS chip with micro-patterned pillars enhanced growth, survival, morphology, neural orientation and alignment of SGNs in vitro compared to control. Smaller spacing (0.8–1.6 µm) between protruding pillars on CMOS led SGNs to develop structured and guided neurites oriented along three topographical axes separated by 60°. We found morphological basis for positioning of the micro-electrodes on the chip that was appropriate for direct contact of SGNs with them. This configuration allowed CMOS electrode array to electrically stimulate the SGN whose responses were observed with live Fluo 4 calcium imaging.

spiral ganglion neurons ; cochlear implants

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

8

2018.

7446

19

objavljeno

2045-2322

10.1038/s41598-018-25814-w

Trošak objave rada u otvorenom pristupu

Povezanost rada

Biologija, Fizika, Interdisciplinarne prirodne znanosti

Poveznice
Indeksiranost