Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

Synergy of sequential injection analysis and molecular recognition technology for low-level 90Sr activity determination (CROSBI ID 665922)

Prilog sa skupa u časopisu | sažetak izlaganja sa skupa

Coha, Ivana ; Dulanská, Silvia ; Grahek, Željko ; Štofaníková, Michaela ; Tucaković, Ivana Synergy of sequential injection analysis and molecular recognition technology for low-level 90Sr activity determination // Czech Chemical Society Symposium Series. 2018. str. 121-121

Podaci o odgovornosti

Coha, Ivana ; Dulanská, Silvia ; Grahek, Željko ; Štofaníková, Michaela ; Tucaković, Ivana

engleski

Synergy of sequential injection analysis and molecular recognition technology for low-level 90Sr activity determination

The routine monitoring, as a part of radiation protection from radioactive materials released into the environment, is established in many countries worldwide. A radionuclide of particular interest is Sr-90, which is, due to its long half-life, one of the most hazardous radionuclide. As it is pure beta emitter, its isolation prior determination is necessary. In recent years, materials based on solid phase extraction are used as a replacement for purification steps of conventional methods, which are mostly time consuming and labor intensive. The introduction of such materials provide partial automatization and miniaturization of separation procedures. Theproductsbasedonmolecularrecognitiontechnology , AnaLigSr-01 and SuperLig 620, provided by IBC Technologies, more known as materials encased in EmporeTM Strontium RAD Disks, are promising materials, since it is possible in short time to separate Sr2+ from many interfering cations, which are present in much higher concentrations, such as Na+, K+, Mg2+, Ca2+ etc. The drawback of these materials is that they, besides Sr2+, sorbPb2+ andBa2+. Thesecationsmayinterfereduring measurements on available instrumentation. Therefore, within this research an extensive study is done to effectively separate strontium from these elements. The goal is to develop rapid and easy to handle method for precise determination of strontium, with detection limits below 50 mBq/L. The final results show, that by changing pH ormolarityofcomplexingagents, purefractionsofPb2+, Sr2+ or Ba2+ can be obtained.

strontium ; separation ; SuperLig 620

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

121-121.

2018.

nije evidentirano

objavljeno

Podaci o matičnoj publikaciji

Czech Chemical Society Symposium Series

2336-7202

Podaci o skupu

18th Radiochemical Conference (RadChem 2018)

predavanje

13.05.2018-18.05.2018

Mariánské Lázně, Češka Republika

Povezanost rada

Interdisciplinarne prirodne znanosti, Kemija

Poveznice