Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations (CROSBI ID 254988)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Kralik, Ivana ; Faj, Dario ; Lauc, Tomislav ; Škarica, Matko ; Popić, Jelena ; Brkić, Hrvoje Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations // Journal of radiological protection, 34 (2018), 4; 1412-1427. doi: 10.1088/1361-6498/aae4e8

Podaci o odgovornosti

Kralik, Ivana ; Faj, Dario ; Lauc, Tomislav ; Škarica, Matko ; Popić, Jelena ; Brkić, Hrvoje

engleski

Dose area product in estimation of effective dose of the patients undergoing dental cone beam computed tomography examinations

Objective To investigate the relationship of the effective dose and dose area product (DAP) in dental cone beam computed tomography (CBCT) examinations and to propose conversion factors for estimation of effective doses of the patients using DAP. Dependence of organ doses on DAP was also investigated. Materials and Methods Different exposure geometries in Cranex3Dx CBCT device were simulated using Monte Carlo simulation and computational anthropomorphic phantom. Then organ doses and effective dose for every exposure geometry was compared to DAP and analysed. Results The effective dose in all simulated CBCT protocols and positions with 180-degrees tube rotation ranged from 5 µSv for 50 x 50 mm2 FOV localized on one tooth using lowest resolution to 265 µSv for the largest FOV and highest resolution. In case of 360-degrees tube rotation the effective dose ranges from 6 µSv to 332 µSv for the same FOV sizes and positions as well as resolutions as in 180-degree tube rotation. Conclusions Though the DAP introduces a large uncertainty in the risk measure in dental CBCT, it represents the dose and field of view (FOV) size which are the most important scanning parameters affecting the dose. To decrease uncertainty in the risk measure, the effective dose has to be estimated for usual clinical positions of the FOV.

CBCT ; DAP ; effective dose ; conversion factors ; Monte Carlo simulations ; organ doses

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

34 (4)

2018.

1412-1427

objavljeno

0952-4746

1361-6498

10.1088/1361-6498/aae4e8

Trošak objave rada u otvorenom pristupu

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje), Fizika, Interdisciplinarne prirodne znanosti

Poveznice
Indeksiranost