Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

In vitro retention of prefabricated and individually formed posts: a pilot study (CROSBI ID 256486)

Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija

Parčina Amižić, Ivana ; Miletić, Ivana ; Baraba, Anja ; Fan, Yuwei ; Nathanson, Dan In vitro retention of prefabricated and individually formed posts: a pilot study // The Journal of prosthetic dentistry, 120 (2018), 4; 553-557. doi: 10.1016/j.prosdent.2018.04.011

Podaci o odgovornosti

Parčina Amižić, Ivana ; Miletić, Ivana ; Baraba, Anja ; Fan, Yuwei ; Nathanson, Dan

engleski

In vitro retention of prefabricated and individually formed posts: a pilot study

STATEMENT OF PROBLEM: Data on the retention of individually formed fiber-reinforced composite posts (everStick) cemented with self-adhesive cement are lacking. PURPOSE: The purpose of this in vitro study was to investigate the pull-out strength of 2 different fiber-reinforced composite posts (prefabricated and individually formed) cemented into extracted teeth with self-adhesive resin cement. MATERIAL AND METHODS: Thirty extracted single-rooted human teeth were decoronated, endodontically treated, and prepared with post spaces of equal length. Prepared specimens were divided into 2 groups (n=15 each) based on the type of post: commercially prefabricated fiber posts (GC) and individually formed resin posts (using GC reinforcing fibers). Self-adhesive resin cement (G-CEM LinkAce ; GC) was used to cement all posts. Each post was held with moderate pressure, and root surfaces were light polymerized for 20 seconds (650 mW/cm2). After cementation, the specimens were stored in saline solution for 30 days. Treated teeth were kept in water for 24 hours before pull-out testing parallel to the longitudinal axis of the posts. Data were analyzed using the Student t test (α=.05) and the coefficient of variance as the ratio of the standard deviation to the mean. RESULTS: The mean pull-out retention strength was 185.7 ±61.2 N for the prefabricated fiber posts and 98.9 ±56.5 N for the individually formed fiber posts (P=.026). CONCLUSIONS: The prefabricated fiber posts exhibited significantly higher retention forces than the individually formed posts.

pull-out, FRC

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

120 (4)

2018.

553-557

objavljeno

0022-3913

1097-6841

10.1016/j.prosdent.2018.04.011

Povezanost rada

Dentalna medicina

Poveznice
Indeksiranost