A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption (CROSBI ID 261742)
Prilog u časopisu | izvorni znanstveni rad | međunarodna recenzija
Podaci o odgovornosti
Petković, Tomislav ; Backenstoss, G. ; Cierjacks, S. ; Furić, Miroslav ; Izycki, M. ; Ljungfelt, S. ; Salvisberg, P. ; Steinacher, M. ; Ullrich, Horst ; Weber, P. ; Weyer H.J.
engleski
A Position-Sensitive Detector System with Subnanosecond Timing and its Utilization in the Measurement of Pion Absorption
A complex position-sensitive, time-of-flight detector was designed at the SIN to be used in the kinematically complete measurements of pion absorption in light nuclei, for the detection of both neutrons and charged particles. Design parameters and TOF properties resulting from the computer calculations and suitable test measurements are given for the system consisting of 200 × 10 × 5 cm3 NE 102A scintillator bars, XP 2230 photomultipliers and discriminator. Position dependence of the timing parameters of the 2 m long NE 102A bar viewed from the ends by photomultipliers has been clearly revealed in our model and experimentally verified.
Position sensitive Detector System with nanosecond timing
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
nije evidentirano
Podaci o izdanju
273 (2-3)
1988.
833-840
objavljeno
0168-9002
1872-9576
10.1016/0168-9002(88)90104-0