Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi !

The association of inflammatory mediators and transient ischemic attack (CROSBI ID 674425)

Prilog sa skupa u zborniku | sažetak izlaganja sa skupa | međunarodna recenzija

Dukić, Lora ; Šimundić Ana-Maria ; Martinić- Popović, Irena ; Lovrenčić-Huzjan, Arijana ; Šerić, Vesna The association of inflammatory mediators and transient ischemic attack // Biochemia Medica. 2012. str. A64-A65

Podaci o odgovornosti

Dukić, Lora ; Šimundić Ana-Maria ; Martinić- Popović, Irena ; Lovrenčić-Huzjan, Arijana ; Šerić, Vesna

engleski

The association of inflammatory mediators and transient ischemic attack

Background: Transient ischemic attack (TIA) develops as consequence of atherosclerosis. Our aim was to evaluate inflammatory mediators and early stages of macroangiopathy and microangiopathy in transient ischemic attack, within 12 hours from the onset of symptoms. Materials and methods: Forty- five patients (22 females, range 48-90 years) with transient ischemic attack and thirty-six controls (15 females, range 55-85 years) were included in study. Serum concentrations of cellular adhesion molecules (ICAM-1), interleukin-6 (IL- 6), C-reactive protein (CRP), glucose, lipid profile and sedimentation rate were determined for all participants. Macroangiopathy was assesed by color doppler measurement of carotid intima media thickness. Degree of cerebral vasoreactivity as early marker of microangiopathy was determined by transcranial doppler ultrasound measurement of breath holding index. Results: Levels of inflammatory mediators ICAM- 1, IL-6 and CRP were significantly increased (371.6 ± 161.8 vs. 301.9 ± 91.6 ng/L, P = 0.026 for ICAM- 1, 6.76 (2.72-18.3) vs. 2.46 (1.5-4.61) pg/mL, P < 0.001 for IL-6 and 8.5 (6.7-14.9) vs. 4.5 (2.8- 5.8) mg/L, P < 0.001 for CRP) in patients with transient ischemic attack. Carotid intima-media thickness was significantly higher (1.22 ± 0.17 vs. 0.86 ± 0.19 mm, P < 0.001) and breath holding index was significantly lower (0.67 ± 0.19 vs. 1.16 ± 0.35%/s, P < 0.001) in patients with TIA compared to controls. Conclusion: Inflammatory mediator levels and carotid intima-media thickness measured within the first 12 hours after onset of TIA symptoms are higher than in controls, which together with breath holding index lower than controls indicates high risk of future stroke

inflammation, atherosclerosis, transient ischemic attack

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

A64-A65.

2012.

objavljeno

Podaci o matičnoj publikaciji

Biochemia Medica

Podaci o skupu

2nd European Joint Congress of EFLM and UEMS and 7th Congress of the Croatian Society for Medical Biochemistry and Laboratory medicine (CSMBLM): Laboratory Medicine at the Clinical Interface

poster

01.01.2012-01.01.2012

Dubrovnik, Hrvatska

Povezanost rada

Biotehnologija u biomedicini (prirodno područje, biomedicina i zdravstvo, biotehničko područje)