crta
Hrvatska znanstvena Sekcija img
bibliografija
3 gif
 Naslovna
 O projektu
 FAQ
 Kontakt
4 gif
Pregledavanje radova
Jednostavno pretraživanje
Napredno pretraživanje
Skupni podaci
Upis novih radova
Upute
Ispravci prijavljenih radova
Ostale bibliografije
Slični projekti
 Bibliografske baze podataka

Pregled bibliografske jedinice broj: 211063

Zbornik radova

Autori: Marović, Gordana; Franić, Zdenko; Senčar, Jasminka
Naslov: Primjeri procjene efektivne doze zračenja
( The Effective Dose Assessment - Some Examples )
Izvornik: Zbornik radova 6.simpozija Hrvatskog društva za zaštitu od zračenja = Proceedings of the Sixth Symposium of the Croatian Radiation Protection Association / Garaj-Vrhovac, Verica ; Kopjar, Nevenka ; Miljanić, Saveta (ur.). - Zagreb : Hrvatsko društvo za zaštitu od zračenja , 2005. 265-270.
Skup: Simpozij Hrvatskog društva za zaštitu od zračenja s međunarodnim sudjelovanjem (6 ; 2005)
Mjesto i datum: Stubičke Toplice, Hrvatska, 18-20.04.2005.
Ključne riječi: effektivna doza; harmonizacija; maksimalna dozvoljena aktivnost;
( effective dose; harmonisation; maximum permissible activity )
Sažetak:
Ideally, limits for radioactive contamination of food should be based on scientific recommendations derived from risk analysis. In practice however economic interests and protection of internal markets compromise radiation standards carefully worked out over the past 60 years. This paper presents European standards for radiocaesium in foodstuffs after the Chornobyl accident and some examples of effective dose assessment of 137Cs. Croatian legislation regulating radiation protection has been harmonised with international and European standards. The calculated maximum permissible activity concentration of 137Cs in water was calculated value of 524 Bq/L. This value was compared with 137Cs activity concentrations measured in some samples processed in Radiation Protection Unit of the Institute for Medical Research and Occupational Health. We also assessed the contribution of ingested 137Cs to the effective dose. For the considered samples, we argue that fractions of measured 137Cs activity concentrations in limit values are very low, in spite of very stringent radiation standards. Consequently, the contribution to the effective dose is very small (< 0.1 mSv).
Vrsta sudjelovanja: Predavanje
Vrsta prezentacije u zborniku: Cjeloviti rad (više od 1500 riječi)
Vrsta recenzije: Međunarodna recenzija
Projekt / tema: 0022001
Izvorni jezik: hrv-eng
Kategorija: Znanstveni
Znanstvena područja:
Fizika,Javno zdravstvo i zdravstvena zaštita,Prehrambena tehnologija



  Verzija za printanje   za tiskati


upomoc