crta
Hrvatska znanstvena Sekcija img
bibliografija
3 gif
 Naslovna
 O projektu
 FAQ
 Kontakt
4 gif
Pregledavanje radova
Jednostavno pretraživanje
Napredno pretraživanje
Skupni podaci
Upis novih radova
Upute
Ispravci prijavljenih radova
Ostale bibliografije
Slični projekti
 Bibliografske baze podataka

Pregled bibliografske jedinice broj: 441891

Časopis

Autori: Pribanić, Tomislav; Peharec, Stanislav; Medved, Vladimir
Naslov: A comparison between 2D plate calibration and wand calibration for 3D kinematic systems
( A comparison between 2D plate calibration and wand calibration for 3D kinematic systems )
Izvornik: Kinesiology: International Journal of Fundamental and Applied Kinesiology (1331-1441) 41 (2009), 2; 147-155
Vrsta rada: članak
Ključne riječi: 3D kinematic system; camera calibration; wand calibration; human motion analysis
( 3D kinematic system; camera calibration; wand calibration; human motion analysis )
Sažetak:
Compared to a 2D plate camera calibration and a traditional 3D calibration cage, it is generally regarded that a wand-based camera calibration of 3D photogrammetric systems is more user-friendly. Not surprisingly, nowadays commercially available 3D kinematic systems for a human motion analysis are offering almost exclusively a wand calibration. Still a 2D calibration plate is continuously used in a number of other applications and it has potential advantages over the wand. However, there appears to be no published work comparing a 2D plate and a wand calibration, at least when it comes to the commercially available 3D kinematic systems. Therefore, in this work we compared a 2D plate calibration and wand calibration for a typical and very popular 3D kinematic system. We demonstrated that there was basically no difference in the reconstruction accuracy and additionally most qualitative issues were, as a rule, favorable to a wand calibration.
Projekt / tema: 034-0362979-2334, 036-0362979-1554
Izvorni jezik: eng
Rad je indeksiran u
bazama podataka:
Scopus
SCI-EXP, SSCI i/ili A&HCI
Science Citation Index Expanded (SCI-EXP) (sastavni dio Web of Science Core Collectiona)
Social Science Citation Index (SSCI) (sastavni dio Web of Science Core Collectiona)
Kategorija: Znanstveni
Znanstvena područja:
Elektrotehnika,Kliničke medicinske znanosti,Pedagogija
URL Internet adrese: http://hrcak.srce.hr/kineziologija?lang=en
Broj citata:
Altmetric:
DOI: UDC 577.3:531.1:796.015.868
URL cjelovitog teksta: http://hrcak.srce.hr/kineziologija?lang=en
Google Scholar: A comparison between 2D plate calibration and wand calibration for 3D kinematic systems
Upisao u CROSBI: tpribanic@fer.hr (tpribanic@fer.hr), 27. Sij. 2010. u 16:48 sati



Verzija za printanje   za tiskati


upomoc
foot_4