Nalazite se na CroRIS probnoj okolini. Ovdje evidentirani podaci neće biti pohranjeni u Informacijskom sustavu znanosti RH. Ako je ovo greška, CroRIS produkcijskoj okolini moguće je pristupi putem poveznice www.croris.hr
izvor podataka: crosbi

An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples (CROSBI ID 166763)

Prilog u časopisu | pregledni rad (znanstveni) | međunarodna recenzija

Breusing, Nicolle ; Grune, Tilman ; Andrišić, Luka ; Atalay, Mustafa ; Bartosz, Grzegorz ; Biasi, Fiorella ; Borović, Suzana ; Bravo, Laura ; Casals, Isidre ; Casillas, Rosario et al. An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples // Free radical research, 44 (2010), 10; 1203-1215. doi: 10.3109/10715762.2010.499907

Podaci o odgovornosti

Breusing, Nicolle ; Grune, Tilman ; Andrišić, Luka ; Atalay, Mustafa ; Bartosz, Grzegorz ; Biasi, Fiorella ; Borović, Suzana ; Bravo, Laura ; Casals, Isidre ; Casillas, Rosario ; Dinischiotu, Anca ; Drzewinska, Joanna ; Faber, Heidemarie ; Mohd Fauzi, Norsyahida ; Gajewska, Agnieszka ; Gambini, Juan ; Gradinaru, Daniela ; Kokkola, Tarja ; Lojek, Antonin ; Luczaj, Wojciech ; Margina, Denisa ; Mascia, Cinzia ; Mateos, Raquel ; Meinitzer, Andreas ; Mitjavila, María Teresa ; Mrakovčić, Lidija ; Munteanu, Maria Cristina ; Podborska, Martina ; Poli, Giuseppe ; Sicinska, Paulina ; Skrzydlewska, Elzbieta ; Vina, Jose ; Wiswedel, Ingrid ; Žarković, Neven ; Zelzer, Sieglinde ; Spickett, Corinne M.

engleski

An inter-laboratory validation of methods of lipid peroxidation measurement in UVA-treated human plasma samples

Lipid peroxidation products like malondialdehyde, 4-hydroxynonenal and F 2 -isoprostanes are widely used as markers of oxidative stress in vitro and in vivo . This study reports the results of a multi-laboratory validation study by COST Action B35 to assess inter-laboratory and intra-laboratory variation in the measurement of lipid peroxidation. Human plasma samples were exposed to UVA irradiation at different doses (0, 15 J, 20 J), encoded and shipped to 15 laboratories, where analyses of malondialdehyde, 4-hydroxynonenal and isoprostanes were conducted. The results demonstrate a low within-day-variation and a good correlation of results observed on two different days. However, high coeffi cients of variation were observed between the laboratories. Malondialdehyde determined by HPLC was found to be the most sensitive and reproducible lipid peroxidation product in plasma upon UVA treatment. It is concluded that measurement of malondialdehyde by HPLC has good analytical validity for inter-laboratory studies on lipid peroxidation in human EDTA-plasma samples, although it is acknowledged that this may not translate to biological validity.

oxidative stress; F2-Isoprostanes; 4.-hydroxynonenal; malondialdehyde

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o izdanju

44 (10)

2010.

1203-1215

objavljeno

1071-5762

10.3109/10715762.2010.499907

Povezanost rada

Kemija, Temeljne medicinske znanosti, Biologija

Poveznice
Indeksiranost