crta
Hrvatska znanstvena Sekcija img
bibliografija
3 gif
 Naslovna
 O projektu
 FAQ
 Kontakt
4 gif
Pregledavanje radova
Jednostavno pretraživanje
Napredno pretraživanje
Skupni podaci
Upis novih radova
Upute
Ispravci prijavljenih radova
Ostale bibliografije
Slični projekti
 Bibliografske baze podataka

Pregled bibliografske jedinice broj: 698518

Zbornik radova

Autori: Dujić Bilušić, Sandra; Džehverović, Mirela; Čakar, Jasmina; Buljugić, Dženisa; Kovačević, Lejla; Pehlić, Marina; Polašek, Ozren; Rudan, Igor; Anđelinović, Šimun; Primorac, Dragan; Škaro, Vedrana; Projić, Petar; Marjanović, Damir
Naslov: Allele frequencies of the New European Standard Set (ESS) loci plus SE33 locus in Dalmatian Human Population
Izvornik: 7th ISABS Conference in Forensic, Anthropologic and Medical Genetics and Mayo Clinic "Lectures in Translational Medicine" : final program and abstracts / Rako, Duje ; Škaro, Vedrana (ur.). - Zagreb : International Society for Applied Biological Sciences - ISABS , 2011. 112-112.
Skup: ISABS Conference in Forensic, Anthropologic and Medical Genetics and Mayo Clinic "Lectures in Translational Medicine" (7 ; 2011)
Mjesto i datum: Bol, IHrvatska, 20.-24.06.2011.
Ključne riječi: New European Standard Set; PowerPlex ESX; Dalmatia
Sažetak:
In response to the ENFSI and EDNAP groups' call fornew STR multiplexes for Europe, Promega developed a suite of four new DNA profiling kits. One of them is PowerPlex ESX 17 that we have used in this study. In previous population studies of Dalmatian (Southern Croatian) human population, 15 STR loci included in the AmpFlSTR®Identifiler® and Powerplex 16 were used. Additionally, we have decide to analyze 6 additional new STR loci (D22S1045, D1S1656, D10S1248, D2S441, D12S391, SE33). This study is based on an observation of representative sample of Dalmatian human population. A total of 120 unrelated individuals from different parts of Dalmatia participated in this study. Qiagen MicroTM Tissue Kit was used for DNA extraction from whole blood, Quantifiler® assay for quantification and PowerPlex ESX 17® System for amplification and detection. The total volume of each reaction was 5 ml. The PCR amplifications have been carried out in ABI 9700 Thermal Cycler. Electrophoresis of the amplification products was performed on an ABI 310 PRISM. Numerical allele designations of the profiles were obtained by processing with Gene Mapper® IDv 3.2 Software. Deviation from Hardy- Weinberg equilibrium, observed and expected heterozygosity, power of discrimination and power of exclusion were calculated. Also, we have compared Macedonian data with data obtained from other neighboring populations with available data for observed loci. Deviation from Hardy–Weinberg equilibrium, observed and expected heterozygosity, exact test of population differentiation and pairwise Fst were calculated within Powermarker v3.25, since power of discrimination and power of exclusion within PowerStats.
Vrsta sudjelovanja: Poster
Vrsta prezentacije u zborniku: Sažetak
Vrsta recenzije: Međunarodna recenzija
Izvorni jezik: ENG
Kategorija: Znanstveni
Znanstvena područja:
Biologija
Puni text rada: 698518.2011_7th_ISABS_Conference_page_112.pdf (tekst priložen 28. Svi. 2014. u 09:48 sati)
URL Internet adrese: http://www.isabs.hr/PDF/ISABS_2011_abstract_book_web.pdf
Upisao u CROSBI: Vedrana Škaro (Vedrana.Skaro@irb.hr), 28. Svi. 2014. u 09:37 sati



  Verzija za printanje   za tiskati


upomoc
foot_4