Pregled bibliografske jedinice broj: 923677

Časopis

Autori: Glavaš, Hrvoje; Vukobratović, Marko; Keser, Tomislav
Naslov: Infrared thermography as control of handheld IPL device for home-use
( Infrared thermography as control of handheld IPL device for home-use )
Izvornik: Journal of Cosmetic and Laser Therapy (1476-4172) 20 (2018), 5; 267-277
Vrsta rada: članak
Ključne riječi: Energy influence ; hair removal temperature ; infrared thermography ; IPL
( Energy influence ; hair removal temperature ; infrared thermography ; IPL )
Sažetak:
Infrared thermography as contactless method for determining the temperature distribution on the surface is used for analyzing the impact of intense pulsed light hair removal device (IPL) on the skin. Depth of light penetration depending of wavelength is described as well as absorption curves and IPL impulse shapes. Energy balance and IPL impulse influence on the skin is analyzed. Melanin temperature rise by different fluence operation and temperature distribution in the modeled hair is used in order to determine overall skin temperature rise. Estimated energy balance provided by mathematical model has been confirmed with experimental results. Performed measurements, beside determination of the right emissivity, required the identification of most significant parameter in the process which proved to be the skin reference temperature and real temperature rise. Practical IPL application with detailed body temperature analysis is comprehensively described and thermal imaging interpretation problem and determination of the temperature rise is observed.
Izvorni jezik: eng
Rad je indeksiran u
bazama podataka:
Current Contents Connect (CCC)
MEDLINE
Scopus
SCI-EXP, SSCI i/ili A&HCI
Science Citation Index Expanded (SCI-EXP) (sastavni dio Web of Science Core Collectiona)
Kategorija: Znanstveni
Znanstvena područja:
Elektrotehnika,Javno zdravstvo i zdravstvena zaštita,Interdisciplinarne biotehničke znanosti
URL Internet adrese: https://www.tandfonline.com/doi/full/10.1080/14764172.2017.1406607
Broj citata:
Altmetric:
DOI: 10.1080/14764172.2017.1406607
URL cjelovitog teksta:
Google Scholar: Infrared thermography as control of handheld IPL device for home-use
Upisao u CROSBI: Hrvoje Glavaš (hrvoje.glavas@etfos.hr), 5. Vel. 2018. u 17:36 sati