Preliminary monitoring results of ventilated heavyweight building envelope from recycled aggregate (CROSBI ID 667212)

Prilog sa skupa u zborniku | izvorni znanstveni rad | međunarodna recenzija

Bagarić, Marina ; Banjad Pečur, Ivana ; Milovanović, Bojan Preliminary monitoring results of ventilated heavyweight building envelope from recycled aggregate // 7th International Building Physics Conference IBPC2018 Preliminary Proceedings - Healthy, Intelligent and Resilient Buildings and Urban Environments. Syracuse (NY), 2018. str. 1441-1446

Podaci o odgovornosti

Bagarić, Marina ; Banjad Pečur, Ivana ; Milovanović, Bojan

engleski

Preliminary monitoring results of ventilated heavyweight building envelope from recycled aggregate

Potential of recycled aggregate concrete (RAC) has already been acknowledged by many researchers, but the focus was primarily on its mechanical and durability properties at material level. If the focus is shifted to element and whole building level, then the question can be raised ; how building envelopes made from RAC behave when exposed to real environment? The present paper describes an experimental set up to monitor hygrothermal behaviour of one three-storey family house built with prefabricated ventilated sandwich wall panels made from recycled concrete and recycled brick aggregate. This type of building envelope can be classified as a heavyweight envelope. In ground-floor flat a wall in the living room facing south is analysed in terms of internal temperature evolution and humidity distribution. Conditions of indoor and outdoor environment were monitored as well. Time lag and decrement of temperature extremes were observed and these benefits can be attributed to the presence of thermal mass. Ventilation of air in cavity ensured acceptable humidity level in all characteristic layers of wall panel. Summer overheating occurred due to insufficiently shaded large transparent openings. Further step is validation of numerical model and assessing the suitability of presented envelope type to different climates. This paper indicates the great potential of RAC application in energy efficient and moisture safe building envelope design.

Recycled aggregate concrete, prefabricated ventilated sandwich panels, heavyweight building envelope, field monitoring, hygrothermal behaviour

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

nije evidentirano

Podaci o prilogu

1441-1446.

2018.

objavljeno

Podaci o matičnoj publikaciji

7th International Building Physics Conference IBPC2018 Preliminary Proceedings - Healthy, Intelligent and Resilient Buildings and Urban Environments

Syracuse (NY):

Podaci o skupu

7th International Building Physics Conference (IBPC 2018)

poster

23.09.2018-26.09.2018

Syracuse (NY), Sjedinjene Američke Države

Povezanost rada

Građevinarstvo