crta
Hrvatska znanstvena Sekcija img
bibliografija
3 gif
 Naslovna
 O projektu
 FAQ
 Kontakt
4 gif
Pregledavanje radova
Jednostavno pretraživanje
Napredno pretraživanje
Skupni podaci
Upis novih radova
Upute
Ispravci prijavljenih radova
Ostale bibliografije
Slični projekti
 Bibliografske baze podataka

Pregled bibliografske jedinice broj: 306411

Zbornik radova

Autori: Bonefačić, Igor; Franković, Bernard; Viličić, Ivan; Glažar, Vladimir
Naslov: Numerical Modelling Of Temperature And Air Flow Distribution In Enclosed Room
Izvornik: Proceedings of the Heat-SET 2007 conference: Heat transfer in components and systems for sustainable energy technologies, Vol. II / Thonon, Bernard (ur.). - Grenoble : Editions-GRETh , 2007. 1055-1062 (ISBN: 2-9502555-3-1).
Skup: Heat-SET 2007 conference: Heat transfer in components and systems for sustainable energy technologies
Mjesto i datum: Chambery, Francuska, 18-20.04.2007.
Ključne riječi: numerical modelling; heat transfer; air flow; enclosed room
Sažetak:
In the paper three-dimensional case of heat transfer and air flow has been presented for enclosed space heating and cooling with unit mounted on the wall. Numerical modelling has been used to analyze effect of space height on temperature and air velocity distribution under standard conditions. Physical processes in two rooms with different heights are modelled using specialized computational fluid dynamics (CFD) software FLUENT. Calculations are carried out in an empty room without any human or mechanical activity and compared with previous experimental measurements. Numerical analysis has shown distinct relationship between room dimensions (height in this case) and state of comfort in the room. Although average values of temperature and air velocity in the room are satisfactory there are local distortions from the standard optimal comfort values. Considerable differences in temperature distribution are observed especially in heating conditions where temperature drop in lower layers of higher room occur due to buoyancy effects. To cancel buoyancy effects it is necessary to increase air inlet velocity from the unit which could lead to local air velocity distortions resulting with disturbed optimal comfort values.
Vrsta sudjelovanja: Poster
Vrsta prezentacije u zborniku: Cjeloviti rad (više od 1500 riječi)
Vrsta recenzije: Međunarodna recenzija
Projekt / tema: 069-0692972-3112
Izvorni jezik: ENG
Kategorija: Znanstveni
Znanstvena područja:
Strojarstvo,Temeljne tehničke znanosti
Puni text rada: 306411.Heat-SET-lanak.pdf (tekst priložen 27. Ruj. 2007. u 12:26 sati)
Upisao u CROSBI: Igor Bonefačić (Igor.Bonefacic@riteh.hr), 27. Ruj. 2007. u 12:26 sati



  Verzija za printanje   za tiskati


upomoc
foot_4