4 gif
Pregledavanje radova
Jednostavno pretraživanje
Napredno pretraživanje
Skupni podaci
Upis novih radova
Upute
Ispravci prijavljenih radova
Ostale bibliografije
Slični projekti
 Bibliografske baze podataka

Pregled bibliografske jedinice broj: 726191

Časopis

Autori: Dediol, Emil; Čvrljević, Igor; Dobranić, Marijan; Uglešić, Vedran
Naslov: Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.
Izvornik: International journal of oral and maxillofacial surgery (0901-5027) 43 (2014), 4; 399-404
Vrsta rada: članak
Ključne riječi: lag screw; mandible fixation; mandible osteosynthesis; mandibulotomy; miniplate
Sažetak:
The mandibular swing approach is a surgical approach for the resection of malignant lesions localized in the posterior oral cavity and oropharynx. We analyzed 15 years of experience with fixation of the straight midline mandibulotomy and compared two fixation methods: lag screws and miniplates. A total of 117 patients underwent a straight midline mandibulotomy during the study period ; 85 had fixation with two lag screws and 32 with two miniplates. The overall complication rate was low and there was no significant difference in complication rate regarding the fixation method (9% for miniplates vs. 7% for lag screws). The most serious complication over the whole study period was non union, which occurred in only two patients, followed by orocutaneous fistula and infection. Radiotherapy did not cause serious complications and is not regarded as hazardous in midline mandibulotomy patients. We conclude that lag screw fixation is at least as safe as miniplate fixation, but because of better fragment compression, offers faster bone healing.
Projekt / tema: 065-1080057-0431, 108-1080057-0043
Izvorni jezik: ENG
Current Contents: DA
Citation Index: DA
Kategorija: Znanstveni
Znanstvena područja:
Kliničke medicinske znanosti,Stomatologija
Tiskani medij: da
URL Internet adrese: http://www.sciencedirect.com/science/article/pii/S0901502713010886
Broj citata:
Altmetric:
DOI: 10.1016/j.ijom.2013.09.003
Google Scholar: Comparative study between lag screw and miniplate fixation for straight midline mandibular osteotomy.